2022 Ground power unit Guantai 180Kva+28DC
2022 Ground power unit Guantai 180Kva+28DC
Contact us for price
Location:Tremblay-en-France, France
orCall +33 640 821 141
Description
GENERATOR SPECIFICATIONS
400 Hz 115/200 volts nominal, +/- 15% adjustable, 3 phases, 4 wire wye-connected, grounded neutral, revolving field, brushless, self-cooling, single bearing, brushless rotating rectifier assembly, directly connected to the engine.
ENGINE SPECIFICATIONS
- 24 volt starting motor - Dry-type air cleaner
- Heavy-duty spark - (2) 12-volt batteries arrestor / silencer
- Full flow fuel filter
- Pusher type fan - De-aerator tank
- Full-flow lubricating oil filter
- Low coolant shutdown
GENERATOR CONTROLS
The GCM displays and latches the fault if any of the above should occur.
ENGINE CONTROLS
On electronic diesel engine versions, the electronic engine governors provide precise frequency regulation and fast transient response. Engine protection such as low oil pressure, high coolant temperature, and over speed
protection are programmed into the engine electronic control module. An engine diagnostic connector is
- Engine hours
- Engine RPM
Specifications
Manufacturer | Unknown |
Year | 2022 |
Condition | Used |
Hours | 150 h |
Gross weight | 2609 kg |
Length | 3962 mm |
Width | 1524 mm |
Height | 1727 mm |
Engine/driveline | emission classEuro 3 |
Additional | units available1 |
- over frequency | 420 Hz in 5 seconds |
- under frequency | 380 Hz in 7 seconds |
- over voltage | 130 volts in 2 seconds |
- under voltage | 100 volts in 7 seconds |
- overload | 125% of rated load for 5 minutes |
- voltage regulation | +/- 1% maximum over full range of generator loading. |
- voltage transient | +/- 13.8% no load to full load. |
- voltage transient recovery time | +/- 1% of nominal Voltage within 100 milliseconds. |
- voltage modulation | 0.5% at steady state. |
- harmonic content | Total harmonic distortion not to exceed 2%. Any single phase harmonic not to exceed 1.5% at 0.8 P.F. linear load. |
- crest factor | 1.414 +/- 0.07 |
- frequency regulation | +/- 0.1% no-load to full-load and overload. |